Evaluating a contamination hazard with a residual gas analyzer
A 1978 NASA technical report by R. Kruger on using a residual gas analyzer to assess contamination hazards, issued for aerospace engineers and spacecraft test staff. The two figures are plain line work: a thermal-cycling graph of test-surface and shroud temperatures against hours, and a dimensioned cylinder schematic labeled for liquid-nitrogen inlet, outlet, and drain tube.