Bridging stiffens the parti-tion considerably and also prevents the passage of fire or vermin.When a partition is ceiled or wainscoted flush with the plaster it isnecessary to cut in bridging between the studding to receive the nails.70. Sliding Door Partitions.—These are made double, the… … WOOD FRAMING. 85 hardly stiff enough for stories exceeding 9^ feet in height, and shouldnever be used for first-class work. If the partition is a bearing parti-tion, one side may be made thicker than the other to carry the floora ove. It is customary in the better class of buildings to sheath…