Construction and standardization of six self inductance coils (1918)
Hsun, Ching Lee · leaf 29
effective length of the suspension. In this manner, thenatural frequency of the suspended coil is brought into resonancewith the impressed alternate current. A current of 10 ampere canbe detected. Obviously a high frequency and low voltage generator shouldbe used. The frequency can rise up to one… … 11 Fig. 8. One side of the condenser is connected to a point N whichcan be shifted along so as to vary r without any change in the re*isistance total R of that branch. Fir3t obtain the steaay currentbalance as in the case of the Wheat stone bridge^ Second, obtain thevariable current balance by…