Cyclopedia of applied electricity : a general reference work on direct-current generators and motors, storage batteries, electrochemistry, welding, electric wiring, meters, electric lighting, electric railways, power stations, switchboards, power transmission, alternating-current machinery, telegraphy, etc. (1916)

American Technical Society · Chicago : American Technical Society · leaf 139

An illustration from Cyclopedia of applied electricity : a general reference work on direct-current generators and motors, storage batteries, electrochemistry, welding, electric wiring, meters, electric lighting, electric railways, power stations, switchboards, power transmission, alternating-current machinery, telegraphy, etc., 1916, leaf 139
iffer by 2;that is yf = yi, ± 2. (i) In a multiplex lap winding, the front and back pitches differ by2x, where x is the number of component simplex windings. (j) Z may be any even number; and in slotted armatures, it must alsobe a multiple of the number of slots; the latter may be even or odd.… … [■Mii^mal t( ^ // \mi£ ^< 2i2^ ><5<5><^><5><>a><><5 Fig. 134. Development of Four-Pole Simplex Wave Winding Froni Bach Front +<2 / 6 f f // /6 C -c 5 /O h h /5 ■4- c +e 9 /■4- b b 3 a 9 -9 /3 X, d d 7 /ft. a Wave Windings. The winding illustrated in…

Electrical engineering

Internet Archive · Northeastern University Library · Public Domain Mark 1.0. Free to use for anything.

More pictures from Cyclopedia of applied electricity : a general reference work on direct-current generators and motors, storage batteries, electrochemistry, welding, electric wiring, meters, electric lighting, electric railways, power stations, switchboards, power transmission, alternating-current machinery, telegraphy, etc.

More like this