tion of either class, when thereis no pressure on the gauge, the needle rests against a stop,which is placed somewhat in advance of the zero-mark, so that 360 EXPERIMENTAL ENGINEERING [§ 2/9. minute pressures are not indicated by the gauge. In the useof the instrument the needle sometimes gets… … Diaphragm-gauge. gauges are also affected by heat. Hence, when set up for use abent tube, termed a siphon, or a vessel which will always containwater, should be interposed between the gauge and the steam.279. Vacuum-gauges.—Vacuum-gauges are constructedin the same method as the Bourdon or diaphragm…