cuts its own thread as THE OPEN TREATMENT OF FRACTURES 763 it sinks into the bone. The principle is good and the screw shouldbe efficient, though the author has had no experience with it.When a screw is driven home it should not be too tightly fixed lestit strip the threads cut in the bone or cause… … Fig. 831.—Appliance for holding plate in position while screws are being placed,ilso holds fracture in reduction. The Four-post Clamp.—Numerous modifications of the four-postclamp have been devised and used with more or less success thoughthey have been almost entirely superseded, in the last few…