Hutton, Frederick Remsen, 1853- [from old catalog] · New York, J. Wiley & sons; [etc., etc.] · leaf 151
condenser in which the propor-tion of the suction which is used as condensing water is;controlled automatically by the float F. The water from thewell enters through an opening 5, and the opening D connectsthe condenser to the suction-orifice of the pump. The 114 MECHANICAL ENGINEERING OF POWER… … 59. The Hot-well—Where there is an excess of waterresulting from mixing the injection with the condensed steamabove that required by the boiler, the air-pump will dischargeinto a hot-well. In engines with surface condensers the hot-well becomes a much less significant organ, because only the…