Hutton, Frederick Remsen, 1853- [from old catalog] · New York, J. Wiley & sons; [etc., etc.] · leaf 506
the upper end while water enters the lower end to supplytheir place. The tubes cannot be readily cleansed nor in-spected by eye except for a short distance. 470 MECHANICAL ENGINEERING OF POWER PLANTS- This type of boiler leads to the class of water-tube boilersmade up of bent tubes entirely, which…
Mechanical engineering · Steam power plants