Mechanical tests of pumps and pumping plants used for irrigation and drainage in Louisiana in 1905 and 1906. (1907)

U.S. Department of Agriculture, Office of Experiment Stations · Washington : Govt. Print. Office · leaf 23

An illustration from Mechanical tests of pumps and pumping plants used for irrigation and drainage in Louisiana in 1905 and 1906., 1907, leaf 23
d to bailer, 28,629 pounds. Equivalent water evaporated from and at 212° F.. .*i.*i, 112 pounds. Boiler horsepower, 24<). Average temperature of fuel oil. 171° F. Average air temperature. 1)2° F. Water apparently evaporated per pound of oil. 9.92 pounds. Equivalent evaporation from and at 212°… … PLANT NO. 4, ABBOTT-DTJSON CANAL, SECOND RELIFT. Located about 3^ miles north of Egan, La., on the main canal ofthe Abbott-Duson canal system, is the second relift. The heightthrough which this plant elevates the water varies with the changinglevel of the canals above and below the plant. During…

Pumping machinery. Irrigation Louisiana. Drainage Louisiana

Internet Archive · Public Domain Mark 1.0. Free to use for anything.

More pictures from Mechanical tests of pumps and pumping plants used for irrigation and drainage in Louisiana in 1905 and 1906.