Steam power plant auxiliaries and accessories; (1922)
Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 373
Air And Water-:Spaces, Fig. 332.—Interlocking Pipe Filling In Mixing Chamber Of Worthington Tower. Note.—In every case, the tower is open at the top, and is so arrangedat the bottom that atmospheric-air will circulate (either by natural draftor by pressure of a fan-blower) through the descending… … -Collecting PanFig. 333.—Burhorn Open Or Atmospheric Cooling Tower. (Louvres removedfrom one side to show construction. In some cities wooden cooling towers are pro-hibited because of fire risk.) Note.—From 75 To 85 Per Cent. Of The Recooling EffectedIn A Cooling-Tower Results From Evaporation in…
Steam power plants · Pumping machinery