Temperature coefficient of magnetic permeability within the working range (1915)

National Bureau of Standards · leaf 9

An illustration from Temperature coefficient of magnetic permeability within the working range, 1915, leaf 9
Fig. i.—Showing normal induction for cast iron at 250 and percentage change in mag-netizing force for a given induction due to 1 degree rise in temperatureC-i, as received C-2, quenched from 1000 C-3, annealed from 900° B … 5 10 IS ^ Fig. 2.—Showing normal induction for wrought iron at 250 and percentage change inmagnetizing force for a given induction due to 1 degree rise in temperatureW-i, as received W-2, annealed from 9000 Sanford] Temperature Coefficient of Permeability standard temperature were permitted. As the…

Magnetism · Magnetic properties and materials A4100 Electricity and magnetism · Fields and charged particles

Internet Archive · NIST Research Library · Public Domain Mark 1.0. Free to use for anything.