is soas to replenish the air that gradually leaks out of the pres-sure tank. Even if there were no difficulty in pumping airinto a high-pressure tank, the accumulator would be pref-erable, because with it the pressure depends upon theweight on top of the plunger, not on the height of the Hydraulic… … Fig. 413 The arrangement of the entire apparatus of an Otis high-pressure vertical elevator is shown in Fig. 413. This iUlustration shows several parts not represented in the eV-mentary diagram, Fig. 412. The main pump is at A and &90 Steam Engineering at B is shown the prime mover, which in…