San Francisco : Architect and Engineer, Inc · leaf 140
on was developed, there will be three banks of suchunits in multiples of twelve, a total of thirty-six units. In order to meet the problems of rust, deterioration,staining, warping, and short life, as well as to attainattractive permanent coloring and a surface easy tokeep clean, glazed wall units… … Snapshot of test for structure and seismic resistance of partitionsfor school shower and dressing compartments. Kraftile TerraCotta Wall Units, reinforced by steel bars and concrete, resultedin a practical monolith. architect of the school, and his chief draftsman, OscarM. Price. The partitions…