Fig. 36. comas within 14 inches of the joists, as is usually the case with base-ment windows, the joists should either be framed into a header, asshown in Fig. 37, or a steel beam should be placed over the opening. WOOD FRAMING. 63 This is a point that must not be overlooked in laying out the… … Fig. 37.—Framing Plan of Floor, Fig. 36. floor joist must always be placed against the walls that are parallelwith the joists to afford a nailing for the ends of the floor boards, 64 B UILDING CONS TR UC TION. laths or furring strip?; in cheap wooden buildings the under flooring is rometimes nailed…