if the floorbeams were all dressed to a pattern there would not be much advantage in cross-furring. As it is, the principal advantage of cross-furringis that it is more practicable to get a level ceiling by it, and the floorbeams may be spaced from 14 to 18 inches apart, while the bearingsfor the… … Fig. 184. furring is put on some time after the beams are set, this unequal de-flection may be in part overcome. On the other hand cross-furringleaves a space between the bottom of the floor joists and the lathssufficient for the passage of vermin and of fire. When the ceiling is to be cross-furred…