336 MASONRY AND REINFORCED CONCRETE The floor-panels were about 12 feet by 25 feet, the girders havinga span of about 12 feet, and the beams a span of 25 feet. Oneintermediate beam was placed in each panel, as shown in the interiorThe girders were 12 inches wide and 20 inches deep below the slab,…