SERvicE piPEi^^S ai^ iron service pipe w4th thestreet main, a section of lead sup-ply being wiped in next the main.The service box and stop-cock at Fig. 72. Service Pipe Carried beneath i • i Foundation Wall. the curb are not shown m the en- graving. The earth under the pipe should be rammed down… … 297 74 PLUMBING and wiped joints. A stop and waste cock should be placed in thesen ice pipe just inside the cellar wall, and in a position where it willbe accessible in case of accident. A drip pipe should be connectedwith the cock tube, for draining away the waste water, which wouldotherwise…