Gas-engines and producer-gas plants; a practice treatise setting forth the principles of gas-engines and producer design, the selection and installation of an engine, conditions of perfect operation, producer-gas engines and their possibilities, the care of gas-engines and producer-gas plants, with a chapter on volatile hydrocarbon and oil engines (1905)
Mathot, Rodolphe Edgard, 1866- · New York N.W. Henley Pub. Co · leaf 72
s the dry meter is the type mostwidely employed. In Sweden and in Holland it is alsogenerally introduced (Fig. 41). In the matter of accuracy of measurement there islittle, if any, difiference between wet and dry meters.The dry meter has the merit of measuring correctly re- DRY METERS 73 gardless… … Fig. 42.—Section through a dry gas-meter. , This is an objection of no great weight; for there isalways enough pressure in the mains and pipes tooperate a meter. In many cases, where the employment of non-freez-ing liquids is necessary, the dry meter may be used to 74 GAS-ENGINES AND PRODUCERS…