Hartford Steam Boiler Inspection and Insurance Company · Hartford, Ct. : Hartford Steam Boiler Inspection and Insurance Co · leaf 76
er cent, of solid plate. 44179 Strength of rivets at joint in No. 00 plate = ^^ ^^5 = 66 per cent, of solid platu l.o<5 X .o5o Strength of rivets at joint in | plate = .44179 1875 X .375 63 per cent, of solid plate. Fig. 8. Plate f thick. Rivet holes 4| diam. Pitch of rivets, 2f. 2 2,5 81*o… … Fig. 8.