Hartford Steam Boiler Inspection and Insurance Company · Hartford, Ct. : Hartford Steam Boiler Inspection and Insurance Co · leaf 91
Fig. 5.Fig. 5. Plate ^ thick. Rivet holes f diam. Pitch of rivets = 2f.Strength of plate at joint = 2.544179x2 Strength of rivets at joint = 2 5 x 3125 = 70 ^ of solid plate.= 113^ of solid plate. 84 THE LOCOMOTIVE. [June, … Fig. 6. Fig. 6. Plate f^ thick. Rivet holes if diam. Pitch of rivets = df. StLgth of p^.ate at joint = ^^^^=^ = 75 ^ of solid plate. Strength of rivets at joint = gl^^g = 102^ of solid plate. The above is the best proportioned double-riveted joint we have seen thus far.Those who maintain that a…
Locomotives · Steam-boiler explosions