Hutton, Frederick Remsen, 1853-1918 · New York, J. Wiley & sons; London, Chapman & Hall, limited · leaf 460
Fig. 339. joints as Fig. 339 will show a strength of 85 per cent of thesolid plate. 218. Failure of the Riveted Joint—While the rivetedjoint fails in one of two generic ways, either by shear of therivets or by failure of the plate, the latter may occur inseveral ways. The rivet may (c) buckle or…
Mechanical engineering · Steam power plants