Mechanical equipment of buildings; a reference book for engineers and architects (1916)
Harding, Louis Allen, Willard, Arthur C. (Arthur Cutts), 1878-1960 · New York Wiley · leaf 396
a substantial concrete foundation withanchor bolts should be provided. Where such foundations are to be made, plans will be sentso that the foundation work can be completed before the arrival of the pump. Piping in General. Run all piping in as direct a line as possible; avoid all unnecessaryturns.… … €-Bfn9 Fig. 29. Single-Stage Double-Suction Gould Pump.TABLE 15 DIMENSIONS OF GOULDS SINGLE-STAGE DOUBLE-SECTION PUMP. Size of Pump Suction andDischarge Flange Dia Bolt Circle Dia No. of Bolts Size of Bolts No. of Bolts in Csg. FSize Bolts in Csg. Ft. A B C D E F G H J K L M N O 434 4 y$ 4 Yl28 M12…