Mechanical equipment of buildings; a reference book for engineers and architects (1916)
Harding, Louis Allen, Willard, Arthur C. (Arthur Cutts), 1878-1960 · New York Wiley · leaf 500
per hour.A = fractional part of the weight of exhaust used to heat the feed water.XS = weight of exhaust condensed in feed water heater per hour,then (1 — X) S = weight of exhaust steam available for heating or drying purposes per hour,and deducting 9 per cent for unavoidable losses leaves (0.91 —… … TTT^ Fig. 2. Arrangement of Exhaust Steam He.\ting Sy.stem. 85 per cent of the weight of the exhaust from the engines is available for heating in the non-con-densing plant with no auxiliaries except the feed pump when the condensation from the radiationis all returned to the feed water heater.…
Building · Heating · Ventilation