,to obviate the necessity for any tearing-up offloors or removal of plaster in order to locate andrepair leaks that may show up after the fixturesare set. Water Test. The water test is usually ap-plied on new work, and is one of the severesttests that can be adopted. Any defective ma- PLUMBING 199… … rig. 48. Illustrating Use of Test Plug in Water Test. soldering the ends shut, if lead is used; by plugsor caps, if iron pipe is used; or by test plugs. Fig. 48 shows one style of test plug. Theseplugs are made in different forms to suit all the 200 PLUMBING uses for which they may be called upon…