ble economy. It may perhaps be of service to detail a few ofof the causes of failure in mill boilers,these corrosion is a very common one.corrosion is the result of acidity in the feed water,which is often caused by the employment of waterheated by means of exhaust steam, especially ifanimal oils… … Fig. 66. neutralising agent is essential. External corrosionis more frequent than internal, and is in most casescaused by dampnesss either caused by leakage orfrom imperfect drainage below the flues and settings.For instance, in the example shown in Fig. 65 therehad been leakage at the seam which…