Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 171
event thepump should be stopped and reprimed. Finally, the bearingsshould be examined to see that the automatic oilers are workingproperly, and the packing glands should be adjusted to allow areasonable leakage from the stuffing-boxes. Leakage from astuffing-box indicates that water is being… … s^Sfeis Piimp ■-Strainer Sec. 173] CENTRIFUGAL AND ROTARY PUMPS 151 Note.—Under No Circumstances Should A Centrifugal PumpBe Run In The Wrong Direction. The right direction is generallyindicated by an arrow (Figs. 154 and 155) cast upon the casing. Whena centrifugal pump is run in the wrong…