of 90-deg. fahr., if the steam-pressure is 125 lb. per sq. in.,gage? The external surface area of 10-in. pipe is 2.816 sq. ft. per ft. of length. DIVISION 12 LIVE-STEAM AND EXHAUST-STEAM SEPARATORS 455. A Live-Steam Separator (Fig. 369) is a device for re-moving entrained water from the steam which… … ■ ^—-T-p-—r-Vj? : To Feed-WaterHeater-.