Steam power plant auxiliaries and accessories; (1922)
Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 408
It should be at least98 per cent, effective when theentrainment amounts to about20 per cent. (2) Its tendencyto reduce the pressure of the steamshould be practically inappre-ciable. (3) It should have storagecapacity equal to about fourtimes the volume of the enginecylinder. (4) It shoidd be… … ■DramI-Hdlf End Section I-Siote Section Fig. 370.—Vertical Sections ThroughCochrane Horizontal Receiver-Sep-arator. 388 STEAM POWER PLANT AUXILIARIES [Div. 12 which is extracted from the steam, and as a reservoir whereinan ample volume of steam (Sec. 458) may be continuouslymaintained while the…
Steam power plants · Pumping machinery
Internet Archive · Library of Congress · Public Domain Mark 1.0. Free to use for anything.