Kidder, Frank E. (Frank Eugene), 1859-1905 · New York, Comstock · leaf 668
shown in thefigure, and they were spaced about 15 feet ai:)art. lengthwise of the REINFORCED CONSTRUCTION. 641 wall. Opposite these vertical rods the withes are 3 inches thick;elsewhere ijA inches thick. In each withe were built )4-inch twistedrods, extending across the wall and placed 12 inches… … Fig. 491. Wall and Floor Construction, Alabama Apartment-house, Buffalo, N. Y. wall gave the greatest stability with the least amount of material.The spaces in the walls were stopped at each floor level, except thatfor purposes of smoke flues or ventilation some of them were moreor less continuous.…