Hartford Steam Boiler Inspection and Insurance Company · Hartford, Ct. : Hartford Steam Boiler Inspection and Insurance Co · leaf 147
Fig Showing Radial Arrangement of Tee-Irons. … The actual stress on the brace may be found by dividing the total pressure on the areasupported by the brace by the cosine of the angle between the brace and the directionof the stress. Or, to arrive at the result without resorting to calculation, lay out the