Fig. 16. Volute Type Pump. Discharge … END SECTIONAL VIEW mtsECTlONAL VIE^ PiQ. 17. Turbine Type Pump—Single Stage. PUMPS 363 and reduce the loss of head in the pump casing to a minimum. A single runner is now used fortotal heads up to and including 150 ft. or 65 lb. per sq. in. pressure. The efficiency of this type,single stage, varies…