Radford's cyclopedia of construction; carpentry, building and architecture. Based on the practical experience of a large staff of experts in actual constrcution work (1909)
Johnson, Alfred Sidney, 1860-, Radford, William A., 1865- · Chicago Radford Architectural Co · leaf 359
ituppi^ la ^/tK Qaf^ Valve Fig. 119. Another Method of Installing a Hydraulic Ram. will enable anyone to install these useful ma-chines, and will open up a profitable field for theplumber in country work. 310 PLUMBING Hot-Water Tank Regulator Fig. 120 illustrates the application of a typi-cal… … Fig. 120. Hot-Water Tank Regulator Installation. stantly to any desired temperature, by movingpointer to Warmer or Cooler, after whichits action is automatic. The valve of the regu-lator is mechanically operated by the expansionand contraction of a brass rod, which is part ofthe regulator inserted…