Inside Out Library

Steam power plant auxiliaries and accessories; (1922)

Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 431

An illustration from Steam power plant auxiliaries and accessories;, 1922, leaf 431
4 lb. per sq. in. pressure for each foot vertical height. Example.—A steam-pressure of 5 lb. per sq. in. in the heating-coil(Fig. 402) will, practically, balance a column of water: 5 -5- 0.5 = 10 fthigh. Hence, the water of condensation will be forced to the trap, ifthe trap-inlet is located less… … Fia. 402. ■Method Of Trapping Condensation From Heating Coil Located On BottomOf Deep Pit. 496. The Location Of An Expansion Trap should be suchthat its operation will not be affected by excessive variationsof temperature occurring in the surrounding atmosphere. 497. The Capacity Of A Steam-Trap…

Steam power plants · Pumping machinery

Internet Archive · Library of Congress · Public Domain Mark 1.0. Free to use for anything.