Steam power plant auxiliaries and accessories; (1922)
Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 225
Wafer Connections On Reverse End— \ \J^:--Live Steam InletExhaust Stzam Outlzi Fig. 217.—Farnsworth Duplex Boiler Feeder. This feeder is recommended by its manufacturers for boiler-feeding in non-condensing plants where water from the mains Cho<mbzr-%; -Chamber-fr 3H C3C^..,.....CTl^.11 >:■.■• … Fig. 218.—Showing Installation Of Duplex Boiler Feeder In Connection With ClosedHeater In Non-Condensing Plant. is fed to the boiler through some sort of feed-water heater.It depends for its operation on a water supply under sufficientpressure to flow to the top of the boiler. Sec. 238]…
Steam power plants · Pumping machinery