refrigerator should not enter the house drain, as it addsone more possible source of trouble, and is not at all necessary, as the waterdischarged is harmless. It should empty into the cellar sink, and may be con-nected with the overflow pipe from the attic tank if convenient. The system which… … Fig. 42. Section showing the installation of the back-vent system A. Soil line D. Branch water pipes B. Main waste E. Branch vent C. Main vent F. Rainwater leader G. Removable tap screwsH. CapI. Fresh air inlet J. House trapK. House sewerL. House drain M. Branch soilN. Screw capF. Area drains T.…