not be sogreat, consequently, the current taken from the line will notbe so great with its corresponding drop in line voltage. The resistance starter is much cheaper than the auto-transformer, which is one reason for its use with small motors.As regards the power taken from the line at starting… … PhaseMotor Fig. 482.—Diagram of three-phase starting compensator having three auto-transformers. Starting Compensators for Polyphase Motors.—For starting two-phase motors two single-phase auto-transformersare used, one connected across each phase, and for starting 414 ELECTRICAL MACHINERY…