efore, there is avail-able 1196.9 — 1151.7 or 45.2 B.t.u., which goes to superheat the steam at the lower pressure. Theamount of superheat or the number of degrees above the saturation temperature, corresponding to 45.2atmospheric pressure, to which the steam after free expansion will be raised is… … To AtmospherePig. \r,. Throttlino Calorimeter and Samplinc. Nozzle. If the original steam contains, say 1 per cent of moisture, it will take 8.5 B.t.u. to evaporatethis moisture at 370.7° F. since the latent heat at this temperature is 854.2 B.t.u. per lb. We will then 36.7have left for…