Practical stationary engineering : in form of questions and answers (1909)
West, Andrew Cassius, 1855- · Boston, Mass. : A.C. West · leaf 185
Figure 46.Tappet Motion Pattern. … NO^ Figure 47.Lever Motion Pattern. 173 DIRECTIONS FOR SETTING UP AND OPERATINGPUMPS. In setting up a pump, the first requisite is to provide a fulland steady supply of water or other fluid. To accomplishthis, observe carefully the following points:— The suction pipe in all cases to be of…
Steam engineering · Steam-engines · Steam-boilers