Steam power plant auxiliaries and accessories; (1922)
Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 165
t free access of air to thesurface of the water in the well. This space should be leftuncovered at the top of the casing. Note.—A Single Centrifugal Pump Should Not Be RequiredTo Lift Water From A Battery Of Wells Or Sumps. A separate 144 STEAM POWER PLANT AUXILIARIES [Div. 4 pump should be… … I-Front Elevation OfSteel Supporting Frame I n-Side Elevation Of ll-Diae Elevation utSteel Supporting Frame Fig. 164.—Centrifugal Pump Drawing Water From A Driven Well. One of the wells may thus be pumped down to the level of the inlets tothe piping. When this occurs, air will enter the piping and…
Steam power plants · Pumping machinery