Steam power plant auxiliaries and accessories; (1922)
Croft, Terrell, 1880- ed, Dufflin, Daniel John, 1911- ed · New York, [etc] McGraw-Hill book company, Inc · leaf 69
DischargeValve-. .-DischargeI Valve Chamber … DischargeValveDeck Fig. 54. -Open Position Of Flat-DiskPump-Valve. Fig. 55.—Water-End Of Single Direct-Acting Steam-Pump With Air-Chamber. Pump should, for low speeds, be about 30 per cent., and forhigh speeds, about 50 per cent., of the piston- or plunger area. Sec. 61] DIRECT-ACTING STEAM PUMPS…