Cold storage, heating and ventilating on board ship (1911)
Walker, Sydney Ferris · New York : Van Nostrand · leaf 74
rating. The reason is,there are losses between the refrigerating plant and the waterthat is being frozen, added to which work has to be done inabstracting heat from the water in reducing it to freezing point,and from the ice after it is actually frozen. The old rule holdshere as everywhere—do not… … HASLAM NAVAL REFRIGERATING SET^ MOUNTED IN TANDEM. Practice allows a one-ton machine for a cold chamber ranging 66 COLD STORAGE ON BOARD SHIP. from a capacity of 800 cubic feet up to 3.000 cubic feet, a two-tonmachine from 3,000 to 6,000 cubic feet, a four-ton machine from10,000 to 20.000 cubic…
Ships -- Heating and ventilation · Cold storage on shipboard