Kidder, Frank E. (Frank Eugene), 1859-1905 · New York, Comstock · leaf 778
i of an inch. 637. CAST-IRON ARCH GIRDERS.*—These also are some-times used to support brick and … X JU stone walls in which the openingsare from 10 to 30 feet in width.Fig. 592 shows one of this kind ofgirtlt-rs used to support a centraltower over the crossing of thenave and transept in St. JohnsChurch, Stockton, Cal., Mr.A. Page Brown, architect. Theclear span is 29^/3 feet, and theheight of…