counter-flashingsare to be placed, built into the brickwork as above specified; or,where the vertical surfaces are of shingle or siding, they are to ex-tend under such surfaces at least 6 inches. All valleys are to be lined with 5-lb. lead extending 6 inchesunder shingles at each side. Eave-Trough… … 2 5 o gSi CONTRACTS AND SPECIFICATIONS 93 All work in connection with the eave-troughs and conductors isto be riveted when possible, and all joints soldered; and the expan-sion and contraction from changes in temperature are to be guardedagainst by expansion joints or loose ends. CARPENTER WORK…