run it. The difficulty with the Ransom condenser was thetrouble from the air. The pot had to be very tight, and theaspiration devices were not entirely satisfactory. 108 MECHANICAL ENGINEERING OF POWER PLANTS. 55. The Siphon or Injector Condenser.—Belonging tothe class of gravity condensers, so far… … Fig. 78 the discharge in the hot-well and locating the condenser at theheight of 34 feet above the level of the water in such well are CONDENSING AND NON-CONDENSING ENGINES. IO9 retained, but there is no pot as in the Ransom design. Fromthe section shown in Fig. 78 it will appear that the…