Inside Out Library · Explore

Mechanical equipment of buildings; a reference book for engineers and architects (1916)

Harding, Louis Allen, Willard, Arthur C. (Arthur Cutts), 1878-1960 · New York Wiley · leaf 100

An illustration from Mechanical equipment of buildings; a reference book for engineers and architects, 1916, leaf 100
Pa., broken.7—Lackawanna, Pa., No. 1 B8—Lackawanna, Pa., Rice. . . 100.92.580.80.67.587.73. 9.5 8.77.67.66.48.57.57. No. 1 Semi-bituminous.No. 2, 3, 4, 5 Bituminous.No. 6, 7, 8 Anthracite. High furnace temperatures may be maintained which allow the use of cheap coals runninghigh in volatile matter… … Air Duct Soot Cha.mberFig. 6. Section of Water-Tube Boiler with High Setting. or to the tubes and stack. The extra cost involving the use of high boiler settings is many timesoffset by the gain due to their use, and high settings are just as advantageous in small as in largeplants. 88 POWER PLANTS…

Building · Heating · Ventilation

Internet Archive · University of Toronto, Robarts Library · Public Domain Mark 1.0. Free to use for anything.

More pictures from Mechanical equipment of buildings; a reference book for engineers and architects