mary 218 STEAM POWER PLANT AUXILIARIES [Div. 7 heater. It is usual therefore to select secondary heaters of the closedtype. The primary heater is always of the closed type. 252. Installation Of Primary And Secondary Feed-WaterHeaters, To Be Operated Alternately (Fig. 225), may be advis-able for… … ■Discharge: Feed-Sump Suction- KSteam-SuppluPipe- KAirPump feed-Pump Suction- ^Steam-Supply Pipe- ^AirPump Fig. 225.—Installation Of Primary And Secondary Heaters For Alternate Operation. sionally inoperative on account of the main engine beingrequired to exhaust to the atmosphere. With such…