atlower speeds there is a discharge from the battery through the motor-generator. 411 This unit is sometimes fitted with a three-position switch having anIdle position which disconnects the battery from the motor-gen-erator but leaves the ignition turned on. STARTER: The motor-generator acts as a… … No. 469—Model 1213 Motor Generator 441 BIJUR STARTING MOTORS PERFORMANCE: When no gear ratio is given, the torque is measuredfrom the armature shaft. When a gear ratio is given, the torque is measured from the auxiliaryor gear shaft. Gear Running Free Locked Torque in Type Model Ratio R.P.M.…